BVYLW - 17142 MAGENTA MILC22750E M6-036 EPOXY PART A
- MSDS: BVYLW
- Manufacturer: CRAWFORD LABORATORIES INC
- Product Name: 17142 MAGENTA MILC22750E M6-036 EPOXY PART A
- National Stock Number: 8010-01-350-2681
Product Identification
Product ID:17142 MAGENTA MILC22750E M6-036 EPOXY PART A
MSDS Date:08/26/1994
FSC:8010
NIIN:01-350-2681
Kit Part:Y
MSDS Number: BVYLW
Responsible Party
CHICAGO, IL 60609
US
Emergency Phone: 800-424-9300 CHEMTREC
Info Phone: 312-376-7132
Cage: DO165
Contractor
Telephone: 312-376-7132
Cage: 5V430
Ingredients
METHYL ETHYL KETONE (SARA III) (VAPOR PRESSURE 71.2 MM HG)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 5-20%
OSHA PEL 100 PPM
ACGIH TLV: 200 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
REACTION PRODUCTS OF EPICHLOROHYDRIN & BISHPHENOL A
CAS: 25085-99-8
Fraction By Weight: 5-20%
TOLUENE (SARA III) (VAPOR PRESSURE 38 MM HG)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 5-20%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM;STEL 150 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
100 SOLVENT (VAPOR PRESSURE 9 MM HG)
CAS: 64742-95-6
Fraction By Weight: 1-5%
OSHA PEL 50 PPM
ACGIH TLV: 50 PPM
TITANIUM OXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 5-20%
ACGIH TLV: 10 MG/M3
AMORPHOUS SILICA (TITANIUM OXIDE CONTAINS 0-10% AMORPHOUS
CAS: 112926-00-8
RTECS: VV8850000
ALUMINIUM HYDROXIDE (TITANIUM OXIDE CONTAINS 0-9% ALUMINUM
CAS: 21645-51-2
RTECS: BD0940000
SILICON DIOXIDE
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: 5-20%
ACGIH TLV: 0.1 MG/M3
293 G/L
RTECS: 9999999VO
Hazards
Reports of Carcinogenicity:NTP:UNKNOWN IARC:YES
Health Hazards Acute and Chronic:OVEREXPOSURE MAY PRODUCE VARIOUS
EFFECTS, INCLUDING: ACUTE TOXICITY, RESULTING IN HEADACHE,
DIZZINESS, NAUSEA, LOSS OF CONSCIOUSNESS. SEVER EYE IRRITATION,
RESULTING IN PERMANENT DAMAGE. IRRITATED MUC OUS MEMBRANES.
VOMITING DUE TO INGESTION. DEFATTING & DRYING OF SKIN.
SENSITIZATION AFTER REPEATED CONTACT.*
Explanation of Carcinogenicity:IARC HAS CONCLUDED THAT THERE IS LIMITED
EVIDENCE FOR THE CARCINOGENICITY OF CRYSTALINE SILICA TO HUMANS.
Effects of Overexposure:* PROLONGED OVEREXPOSURE DUE TO INHALATION MAY
CAUSE DELAYED LUNG DISEASE (SILICOSIS). REPORTS ASSOCIATE REPEATED
& PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT
BRAIN & NERVOUS SYSTE M DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING AND INHALING THE CONTENTS MAY BE HARMFUL OR FATAL.
First Aid
First Aid:NEVER GIVE UNCONSCIOUS PERSON LIQ.EYE:FLUSH W/LUKEWRM H2O 15
MIN,LIFT EYELID.GET MED AID.INHAL:REMOVE TO FRESH AIR.GIVE OXYGEN
IF BREATH DIFFICULT.GIVE ARTIF RESP IF NO BREATH.GET MED AID.KEEP
WARM & COMFORTBL.INGEST:CALL DR IMMED.INDUCE VOMIT ONLY ON DR'S
INSTRUCTN.IF VOMIT OCCURS,KEEP HEAD BELOW HIP.SKIN:FLUSH W/H2O
WHILE REMOVING CONTAM CLOTH&SHOES.WASH W/SOAP&WATER.IF IRRIT,GET
MED AID.
Fire Fighting
Flash Point Method:SCC
Flash Point:22.0F,-5.6C
Lower Limits:0.9
Extinguishing Media:FOAM, CO2, OR DRY CHEMICAL
Fire Fighting Procedures:WATER MAY BE USED TO KEEP EXPOSED CONTAINERS
COOL, & TO KEEP FLAMMABLE STRUCTURES WET. DON'T ENTER FIRE AREA
W/OUT PROPER PROTECTION (HZD DECOMP MAY BE PRESENT)
Unusual Fire/Explosion Hazard:WATER PRESSURE MAY SPREAD A FLAMMABLE
LIQUID FIRE. SEALED CONTAINERS MAY EXPLODE IF OVERHEATED.
Accidental Release
Spill Release Procedures:WARNING-FLAMMABLE. ELIMINATE IGNITION SOURCES.
HANDLING EQUIPMENT MUST BE GROUNDED TO PREVENT SPARKING. SOAK UP
WITH AN ABSORBENT AND PLACE IN NON-LEAKING CONTAINERS. SEAL TIGHTLY
FOR PROPER DISPOSAL.
Handling
Handling and Storage Precautions:FLAMMABLE.KNOW DOT REGS BEFORE
TRANSPORTING.WARNING:HOT ORGANIC CHEM VAPORS/MISTS SUSCEPTIBLE TO
SUDDEN SPONTANEOUS COMBUSTION W/AIR.IGNIT MAY OCCUR *
Other Precautions:* AT TEMP
CHANGE.IGNIT MAY OCCUR AT TYPICAL ELEVATED TEMP PROCESS CONDITIONS,
ESP IN PROCESS OPERATING UNDER VACUUM IF SUDDEN ##
Exposure Controls
Respiratory Protection:IMPORTANT-MUST PROVIDE ADEQUATE VENTILATION TO
MAINTAIN VPOR CONCENTRATION BELOW ESTABLISHED TLV AS GIVEN BY OSHA.
IN MORE CONFINED AREAS A NIOSH/MSHA APPROVED RESPIRATOR EQUIPPED
WITH ORGANIC VAPOR C ARTRIDGE SHOULD BE WORN.
Ventilation:MUST PROVIDE ADEQUATE VENTILATION, SEE RESPIRATORY
PROTECTION INFORMATION.
Protective Gloves:USE RUBBER GLOVES
Eye Protection:WEAR SAFETY GOGGLES &/OR FACE SHIELD
Other Protective Equipment:HAVE EYE BATH AND SAFETY SHOWER AVAILABLE.
Work Hygienic Practices:DO NOT REUSE CONTAMINATED CLOTHING OR SHOES.
Supplemental Safety and Health
** OTHER PRECAUTIONS CONT'D: INGRESS OF AIR OR OUTSIDE PROCESS EQUIP
OPERATING UNDER ELEVATED PRESSURE IF SUDDEN ESCAPE OF VAPOR/MISTS
TO ATMOSPHERE OCCURS. ANY PROPOSED USE OF PRODUCT IN ELEVATED TEM
PERATURE PROCESSES SHOULD BE THOROUGHLYEVALUATED TO ASURE THAT SAFE
OPERATING CONDITIONS ARE ESTABLISHED & MAINTAINED.
Chemical Properties
Boiling Pt:B.P. Text:174 TO 344F
Vapor Density:> AIR
Evaporation Rate & Reference:3.44 X N-BUTYL ACETATE
Appearance and Odor:RED/PURPLE LIQUID
Percent Volatiles by Volume:35.4
Stability
Stability Indicator/Materials to Avoid:YES
MAY BE INCOMPATIBLE WITH OXIDIZING AGENTS AND STRONG ALKALIES.
Stability Condition to Avoid:AVOID HEAT, SPARKS, OPEN FLAMES, AND
INCOMPATIBILITIES.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION FOR PRODUCTS
LIKE THIS MAY GENERATE HIGHLY POISONOUS CARBON MONOXIDE AND OTHER
TOXIC GASES.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH CURRENT
LOCAL, STATE, AND FEDERAL REGULATIONS. CONTACT AN APPROVED DISPOSAL
FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.